{"id":3476,"date":"2026-09-03T15:54:58","date_gmt":"2026-09-03T07:54:58","guid":{"rendered":"https:\/\/www.rettar.com\/en\/?post_type=products&#038;p=3476"},"modified":"2026-09-14T15:16:31","modified_gmt":"2026-09-14T07:16:31","slug":"140ghz-radar-level-meter","status":"publish","type":"products","link":"https:\/\/www.rettar.com\/en\/products\/140ghz-radar-level-meter\/","title":{"rendered":"140GHz Radar Level Meter"},"content":{"rendered":"<table>\n<thead>\n<tr>\n<th>\n<div class=\"ybc-p\">Product Type<\/div>\n<\/th>\n<th>\n<div class=\"ybc-p\">Applications<\/div>\n<\/th>\n<th>\n<div class=\"ybc-p\">Max. Range<\/div>\n<\/th>\n<th>\n<div class=\"ybc-p\">Process Temperature<\/div>\n<\/th>\n<th>\n<div class=\"ybc-p\">Protection Rating<\/div>\n<\/th>\n<th>\n<div class=\"ybc-p\">Certification<\/div>\n<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>\n<div class=\"ybc-p\">CPR6400 Liquid (Rod Antenna)<\/div>\n<\/td>\n<td>\n<div class=\"ybc-p\">Liquid level measurement, general process conditions<\/div>\n<\/td>\n<td>\n<div class=\"ybc-p\">50m<\/div>\n<\/td>\n<td>\n<div class=\"ybc-p\">-40\u00b0C to +200\u00b0C<\/div>\n<\/td>\n<td>\n<div class=\"ybc-p\">IP67<\/div>\n<\/td>\n<td>\n<div class=\"ybc-p\">Ex ia IIC T6\/T2 Ga, Exd ia<br \/>\nIIC T6\/T2 Gb, Ex iaD tD A21<br \/>\nIP67 T80\u00b0C\/T290\u00b0C;<br \/>\nCU-TR 012COC Certificate,<br \/>\nCU-TR 020 DOC Certificate,<br \/>\nRussian PAC Certificate,<br \/>\nATEX, IECEX (in progress)<\/div>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<div class=\"ybc-p\">CPR6400 Integrated<\/div>\n<\/td>\n<td>\n<div class=\"ybc-p\">Integrated level measurement for compact installations<\/div>\n<\/td>\n<td>\n<div class=\"ybc-p\">50m<\/div>\n<\/td>\n<td>\n<div class=\"ybc-p\">-40\u00b0C to +200\u00b0C<\/div>\n<\/td>\n<td>\n<div class=\"ybc-p\">IP67<\/div>\n<\/td>\n<td>\n<div class=\"ybc-p\">Ex ia IIC T6\/T2 Ga, Exd ia<br \/>\nIIC T6\/T2 Gb, Ex iaD tD A21<br \/>\nIP67 T80\u00b0C\/T290\u00b0C;<br \/>\nCU-TR 012COC Certificate,<br \/>\nCU-TR 020 DOC Certificate,<br \/>\nRussian PAC Certificate,<br \/>\nATEX, IECEX (in progress)<\/div>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<div class=\"ybc-p\">CPR6400 Process Sealed<\/div>\n<\/td>\n<td>\n<div class=\"ybc-p\">Process-sealed liquid measurement, hygienic \/ sealed vessels<\/div>\n<\/td>\n<td>\n<div class=\"ybc-p\">50m<\/div>\n<\/td>\n<td>\n<div class=\"ybc-p\">-40\u00b0C to +200\u00b0C<\/div>\n<\/td>\n<td>\n<div class=\"ybc-p\">IP67<\/div>\n<\/td>\n<td>\n<div class=\"ybc-p\">Ex ia IIC T6\/T2 Ga, Ex db ia<br \/>\n[ia Ga] Il C T6\/T2 Gb, Ex tb[ia Da] IIC T80%C\/T290\u00b0C Db,Ex db iajia Ga) IIC T6\/T2 Gb,Ex tb [ia DajlC T80\u00b0C<br \/>\n\/T290\u00b0C Db<\/div>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<div class=\"ybc-p\">CPR6400 Hygienic<\/div>\n<\/td>\n<td>\n<div class=\"ybc-p\">Hygienic applications (food, pharmaceutical, bioprocessing)<\/div>\n<\/td>\n<td>\n<div class=\"ybc-p\">50m<\/div>\n<\/td>\n<td>\n<div class=\"ybc-p\">-40\u00b0C to +200\u00b0C<\/div>\n<\/td>\n<td>\n<div class=\"ybc-p\">IP67<\/div>\n<\/td>\n<td>\n<div class=\"ybc-p\">Ex ia IIC T6\/T2 Ga, Ex db ia<br \/>\n[ia Ga] Il C T6\/T2 Gb, Ex tb[ia Da] IIC T80%C\/T290\u00b0C Db,Ex db iajia Ga) IIC T6\/T2 Gb,Ex tb [ia DajlC T80\u00b0C<br \/>\n\/T290\u00b0C Db<\/div>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<div class=\"ybc-p\">CPR6900 Solid (Plastic Horn Antenna)<\/div>\n<\/td>\n<td>\n<div class=\"ybc-p\">Solid \/ bulk material level measurement<\/div>\n<\/td>\n<td>\n<div class=\"ybc-p\">125m<\/div>\n<\/td>\n<td>\n<div class=\"ybc-p\">-40\u00b0C to +200\u00b0C<\/div>\n<\/td>\n<td>\n<div class=\"ybc-p\">IP67<\/div>\n<\/td>\n<td>\n<div class=\"ybc-p\">Ex ia IIC T6\/T2 Ga, Ex db ia<br \/>\n[ia Ga] Il C T6\/T2 Gb, Ex tb[ia Da] IIC T80%C\/T290\u00b0C Db,Ex db iajia Ga) IIC T6\/T2 Gb,Ex tb [ia DajlC T80\u00b0C<br \/>\n\/T290\u00b0C Db<\/div>\n<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n","protected":false},"excerpt":{"rendered":"<p>The CFR6400 and CFR6900 series radar level meters use FMCW frequency modulated continuous wave technology for 140 GHz radar level meters. The radar emits a 120-140GHz high-frequency microwave signal with linear frequency modulation, which is emitted from the radar antenna. When the microwave signal encounters the surface of the measured medium, some of its energy is reflected back by the surface of the medium and received by the radar antenna. A part of the microwave transmitting signal in radar is mixed with the received signal to obtain the difference frequency signal.The differential frequency signal is obtained by Fourier transform algorithms such as FFT or DFT to obtain the differential frequency spectrum signal, thereby obtaining the frequency difference.According to the linear frequency modulation signal frequency difference is proportional to time thus the time difference is obtained. Based on the time difference and the distance between the antenna and the surface of the measured medium, the distance between the antenna and the surface of the measured medium can be calculated.<\/p>\n","protected":false},"featured_media":3477,"parent":0,"menu_order":0,"template":"","tags":[],"product":[497],"size":[],"material":[],"class_list":["post-3476","products","type-products","status-publish","has-post-thumbnail","hentry","product-radar-level-meter","post1-3476"],"acf":[],"_links":{"self":[{"href":"https:\/\/www.rettar.com\/en\/wp-json\/wp\/v2\/products\/3476","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.rettar.com\/en\/wp-json\/wp\/v2\/products"}],"about":[{"href":"https:\/\/www.rettar.com\/en\/wp-json\/wp\/v2\/types\/products"}],"version-history":[{"count":1,"href":"https:\/\/www.rettar.com\/en\/wp-json\/wp\/v2\/products\/3476\/revisions"}],"predecessor-version":[{"id":3479,"href":"https:\/\/www.rettar.com\/en\/wp-json\/wp\/v2\/products\/3476\/revisions\/3479"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.rettar.com\/en\/wp-json\/wp\/v2\/media\/3477"}],"wp:attachment":[{"href":"https:\/\/www.rettar.com\/en\/wp-json\/wp\/v2\/media?parent=3476"}],"wp:term":[{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.rettar.com\/en\/wp-json\/wp\/v2\/tags?post=3476"},{"taxonomy":"product","embeddable":true,"href":"https:\/\/www.rettar.com\/en\/wp-json\/wp\/v2\/product?post=3476"},{"taxonomy":"size","embeddable":true,"href":"https:\/\/www.rettar.com\/en\/wp-json\/wp\/v2\/size?post=3476"},{"taxonomy":"material","embeddable":true,"href":"https:\/\/www.rettar.com\/en\/wp-json\/wp\/v2\/material?post=3476"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}