| Parameter Type | Specific Value |
|---|---|
| Measured Medium | Liquids, viscous media, powders and particles |
| Ambient Temperature | −40 to +80 °C |
| Operating Temperature | −40 to +115 °C |
| Operating Pressure | −1 to 25 bar |
| Output Signal | 1 PNP channel; 1 NPN channel |
| Measurement Hysteresis | ±1 mm |
| Repeatability | ±1 mm |
| Response Time | 0.2 s |
| Damping Delay | 0.2–5 s, adjustable in 10 steps |
| Alarm Delay | 0–99 s, adjustable |
| Dielectric Strength | 500 VAC |
| Operating Frequency | 50–200 MHz |
| Operating Voltage | 12–32 VDC |
| Operating Current | 9 mA |
| Power | 0.28 W |
| Process Connection | G1/2 thread |
| Wetted Material | PEEK + SS316L; PEEK + SS304 |
| Process Seal | FKM sealing ring |
| Probe Material / Surface Roughness | PEEK / Ra < 0.8 μm |
| Electrical Connection | 4-core M12 connector; 4-core cable lead-out type |
| Protection Rating | IP67 |
| Commissioning | Handheld communicator / PC software |
| Output Load Current | Maximum 20 mA per channel |
| Voltage Drop | < 2 V |
| Yellow Status LED | On for 1 s at startup, then off; on when a fault occurs |
| Green Status LED | On when the alarm condition is met; off when it is not met |
Download
Get all the technical details you need by downloading our product specs.